XCESS-Curatia The guiding catheter is designed to provide a controllable delivert channel for the introduction of interventional/diagnostic instruments into the coronary or peripheral vascular sysem.
The unique composit material and brading technology achieves a fast response of 1:1 torque, providing excellent maneuverability and kink resistance.
The 0.071" large internal cavity design , provides a fast delivery channel for equipment to meet the needs of clinical operations for complex lesions.
The Kit consists of a hemostatic valve , a guide wire twister,and a guide wireguide needle.The hemostatic valve is mainly used for a delivery channel and maintains 51 head-end shapes to meet various cardiovascular or peripheral vascular interventions.
The Bioteq Sheath Introducer Kit is intended to provide access and facilitate the percutaneous introduction of various devices into veins and/ or arteries while maintaining hemostasis for a variety of diagnostic and therapeutic procedures.
Features
General Dilation
Taper tip design to reduce tissue trauma
Seamless Transition
From dilator of sheath for smooth penetration
Anti-kinking Sleeve
With radiopaque sheath for stability and strength through tortuous anatomy
Rotatable Suture Eye
Allows easy to adjust the positioning of the suture ring for attachment to the patient
Three-part Braided nylon designs are typically used for applications that require high torque, burst pressure resistance, pushability, steerability and kink resistance(Optimum torque control and kink resistance due to its double mesh).
Soft,radiopaque nylon for minimal vessel trauma
Large than standard inner diameter allows higher flow rate with less resistance.
Body
Braided Nylon for torque responsive and stability
Proximal Segment
Non-braided nylon for maximum flexibility and shape retention
The Direct-Stent® Stent Graft is a multi-layered stent graft with a U.S. patented intravascular hybrid open-closed cell design. It has highest Radial Force compared to other stent grafts.
Features
Strength of a hybrid cell stent design with sent ends that can be flared
Cobalt Chromium Alloy
Flexible srut links for easy navigation in tortuos and distal lesions
ePTFE polymer with proprietary microporous technology
Clinically proven bio-compatible polymer
Semi-Compliant balloon material
Entry profile as low as 1mm
Specifications
Balloon System
Optimal Deployment Pressure
Nominal Pressure
Rated Burst Pressure
Rx Rapid Exchange Balloon Catheter
8 atm
6 atm
16atm
Minimum Guiding Catheter
Crimped Profile
Tip Entry Profile
Recommended Guirewire